WARNING: Exposure to UV light could burn the skin and can cause severe and permanent eye damage by burning the retina. Do not look directly at the UV light.

WARNING: Before replacing the UV lamp, make sure the power source is disconnected or turned OFF.

NOTE: Do not touch the glass portion of the germicidal UV lamp with bare hands. Use cotton gloves to avoid skin oils that will harm the UV lamp.

NOTE: Use only original American-LightsŪ UV lamps. Other lamps will be incompatible and may damage the air cleaner.

NOTE: American Air & WaterŪ, Inc. highly recommends that a qualified technician performs the germicidal UV lamp replacement. The UV lamp should be replaced as follows:

UV lamp replacement with adjustable coupling - Lamp model UVHOAL300AV/14

  1. Remove the 2 Philips screws on the top of the cover and remove the American-LightsŪ cover.
     
  2. Unscrew the adjustable coupling and gently pull the old lamp until it is free from the coupling.
     
  3. Carefully unplug the UV lamp power plug.
     
  4. Carefully pull out the old UV lamp by holding the lamp base.
  5. UV Lamp with Adjustable Coupling
     

  6. Using gloves, replace the UV lamp into the coupling. Reconnect electrical connection and gently tighten. NOTE: Over-tightening could cause system damage.
     
  7. Replace the cover and tighten the screws. Do not pinch or cut any wires.
     
  8. Power the UV air cleaner. The UV lamp will come on instantly.

IMPORTANT: Dispose of the old UV lamp as a hazardous waste in accordance with local, state and federal regulations or the lamp should be recycled. Please dispose of the used UV lamp properly or send it to American Air & Water for recycling.