UV PRODUCTS
|
|
|
RT Germicidal UV Fixtures for Ultraviolet Air & Surface Disinfection |
The
Recessed Troffers
germicidal ultraviolet fixtures are constructed of die-formed,
one-piece steel and highly reflective aluminum. They are
manufactured to meet hospital, pharmaceutical, clean room and
laboratory UV disinfection requirements. Two models recessed
troffers are available -
with four germicidal UV lamps or a germicidal / illuminating
combination using fluorescent lamps and germicidal UV lamps.
UV Air & Surface Disinfection Recessed Troffers - Technical Specifications
|
Recessed Troffer Models |
Recessed Troffer Fixtures (4’ L x 2’ W x 4¼” D) |
RT-36-2G E
RT-36-2G M |
Exposed Grid "Lay In" (2) GML005 110-277V
Mechanical or Plaster (2) GML005 110-277V |
RT-36-4G E
RT-36-4G M |
Exposed Grid "Lay In" (4) GML005 110-277V
Mechanical or Plaster (4) GML005 110-277V |
RT-2G/2CWE
RT-2G/2CWM |
Exposed Grid "Lay In" (2) GML005 & (2) BLL095 (Cool White) 120V
Mechanical or Plaster (2) GML005 & (2) BLL095 (Cool White) 120V |
RT2G2CW277
RT2G2CW27M |
Exposed Grid "Lay In" (2) GML005 & (2) BLL095 (Cool White) 277V
Mechanical or Plaster (2) GML005 & (2) BLL095 (Cool White) 277V |
PF |
Plaster Frames - Optional adder |
Print the
Recessed Troffer UV fixtures specs /PDF/
|
|
Installation Guidelines
Ceiling height up to 9.5' - One RT-36-2G per 75sq. ft. or one RT-36-4G per
125sq. ft. fixtures required.
Ceiling height 9.5' to 11' - One RT-36-2G per 50sq. ft. or one RT-36-4G per
100sq. ft. fixtures required.
Ceiling height 11' to 14' - One RT-36-2G per 40sq. ft. or one RT-36-4G per 70sq.
ft. fixtures required.
Note: Install RT-362G/2CW as RT-36-2G
WARNING: Care should be taken to ensure that people are not
exposed to direct or reflected UV light. Before lamp cleaning or relamping
always turn the power OFF.
Contact American Air & Water for RT UV Sterilizers prices
|